| Specificatie | 250F15CL | 250F15C | 250F15DL | 250F15D | 250F21CL | 250F21C | 250F21DL | 250F21D |
|---|---|---|---|---|---|---|---|---|
| Nominale bedrijfsspanning | 120 ~ 277VAC | |||||||
| Maximale werkspanning | 320VAC | |||||||
| Nominale bedrijfsfrequentie | 50/60 Hz. | |||||||
| Nominale overspanning | 10 kV | 10 kV | 20 kV | 20 kV | 10 kV | 10 kV | 20 kV | 20 kV |
| Nominale stroomstroom | 5KA | 5KA | 10KA | 10KA | 5KA | 5KA | 10KA | 10KA |
| Maximale stroomstroom | 10KA | 10KA | 20KA | 20KA | 10KA | 10KA | 20KA | 20KA |
| Maximale energie | 300J | 300J | 405J | 405J | 300J | 300J | 405J | 405J |
| Klemspanning | 1200 V | 1150V | 1200 V | 1150V | 1150V | 1100 V | 1150V | 1100 V |
| Overspanningsbescherming L-N | √ | |||||||
| L-G,N-G overspanningsbescherming | √ | √ | √ | √ | ||||
| Ground hole | √ | √ | √ | √ | ||||
| Onderdrukking van lekstroom (GDT) | √ | √ | √ | √ | ||||
| Bescherming tegen overtemperatuur | √ | |||||||
| Diagnostische LED | √ | |||||||
| Nominale belasting van de wisselstroomleiding | 15A | |||||||
| Nominale belasting van de bediening | 0-30 VDC, 1500 mA | |||||||
| Werktemperatuur | -40°C ~ +70°C | |||||||
| Werkvochtigheid | HR96% | |||||||
| Levensduur | lange levensduur | Normaal | lange levensduur | Normaal | lange levensduur | Normaal | lange levensduur | Normaal |
| Certificering | Voor de toepassing van deze verordening geldt de volgende bepalingen: | |||||||