Product Summary
The JL-250F is designed for outdoor lamps and installed between the traditional NEMA socket and the light controller. It is used for rapid transformation to improve the surge protection capability of the NEMA interface lamps. The SPD inside the lamps can be replaced by JL-250F, which is more convenient for installation,maintenance and replacement, and can effectively reduce operation and maintenance costs. The product has built-in surge differential mode + surge common mode protection, which greatly improves the working ability of the light controller in the complex electromagnetic interference environment. The combination design of temperature fuse and MOV+GDT can avoid the deterioration of heating caused by aging and over-energy of MOV. The center of the bottom is equipped with a ground hole design, which can provide the grounding circuit of the lamp controller and improve the common mode suppression ability of the lamp.
Product size
![]()
Product Features
Product certification:ANSI C136.41,UL 1449,UL 773,ROHS,CB,CE,UKCA
Component certification:UL,CUL,TUV,VDE,PSE,CQC,ROHS,REACH
20KV/10KA,10KV/5KA Different protection levels are available
Differential mode + common mode protection(L-N,L-G,N-G)
1.2/50us & 8/20us combined wave performance tests
Center ground hole design
Diagnostic LED
GDT+MOV, prevent MOV aging to form leakage current, longer life
Built-in temperature fuse, over-temperature protection
High strength PC material
Gold-plated signal terminals in phosphor bronze nickel plating, gold-plated in accordance with ASTM B 488
Copper plug
Flat design, less wind resistance
Human mechanical handshake design, more convenient rotation
347VAC and 480VAC versions available
Specifications
|
250F15CL |
250F15C |
250F15DL |
250F15D |
250F21CL |
250F21C |
250F21DL |
250F21D |
|
|
Rated operating voltage |
120~277VAC |
|||||||
|
Max operating voltage |
320VAC |
|||||||
|
Rated operating frequency |
50/60Hz |
|||||||
|
Rated surge voltage |
10KV |
20KV |
||||||
|
Rated surge current |
5KA |
10KA |
||||||
|
Max surge current |
10KA |
20KA |
||||||
|
Max energy |
300J |
405J |
||||||
|
Clamping voltage |
1200V |
1150V |
1200V |
1150V |
1150V |
1100V |
1150V |
1100V |
|
L-N surge protection |
√ |
|||||||
|
L-G,N-G surge protection |
√ |
√ |
√ |
√ |
||||
|
Ground hole |
√ |
√ |
√ |
√ |
||||
|
Leakage current suppression(GDT) |
√ |
√ |
√ |
√ |
||||
|
Over-temperature protection |
√ |
|||||||
|
Diagnostic LED |
√ |
|||||||
|
AC line rated load |
15A |
|||||||
|
Control line rated load |
0-30 VDC, 1500mA |
|||||||
|
Operating temperature |
-40°C ~ +70°C |
|||||||
|
Operating humidity |
HR96% |
|||||||
|
Lifetime |
long-life |
Normal |
long-life |
Normal |
long-life |
Normal |
long-life |
Normal |
|
Certification |
ANSI C136.41-2013,UL 1449,UL 773
|
|||||||
Contact Us at Any Time